1251 datasets found! (Query time: 4 ms)
<< PREV | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | NEXT >>
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Color Reflectance (Spectrophotometer) of IODP Hole 386-M0087A
| Abstract: |
Color reflectance spectrophotometry and colorimetry data from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The data where obtained during the onshore phase of expedition 386 which took place between 2022-02-14 – 2022-03-15 onboard D/V Chikyu. After longitudinal splitting of the core sections, each archive half was scanned by the Tri-Sensor Core Logger (TSCL; NS Design) including a noncontact imaging spectrophotometer (MetaVue VS3200; X-Rite), recording data at 2-cm sampling interval. The obtained data is represented in the L*a*b* color coordinate system, where L* is a total reflectance index ranging 0%–100%, a* is green (<0) to red (>0) chromaticity, and b* is blue (<0) to yellow (>0) chromaticity. L*a*b* values were transferred into RGB values using the MATLAB routine lab2rgb. […] |
| Size: |
494 data points |
https://doi.org/10.1594/PANGAEA.975170 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Moisture and density (MAD) from IODP Hole 386-M0085A
| Abstract: |
Moisture and density (MAD) data from discrete samples from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). During the onshore phase of expedition 386, which took place between 2022-02-14 – 2022-03-15 onboard D/V Chikyu, discrete samples for MAD measurements (bulk density, dry density, grain density, water content, porosity, and void ratio) were taken from the work halves using 10 cubic centimetre syringes at an approx. down-core resolution of every 2 meters. Sampling depths were adapted and slightly modified for layers of special interest, such as tephras. Samples were processed and measured directly after sampling onboard Chikyu. For the measurements themselves samples were transferred to glass beakers of known weight and volume. […] |
| Size: |
9 data points |
https://doi.org/10.1594/PANGAEA.977445 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Color Reflectance (Spectrophotometer) of IODP Hole 386-M0084E
| Abstract: |
Color reflectance spectrophotometry and colorimetry data from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The data where obtained during the onshore phase of expedition 386 which took place between 2022-02-14 – 2022-03-15 onboard D/V Chikyu. After longitudinal splitting of the core sections, each archive half was scanned by the Tri-Sensor Core Logger (TSCL; NS Design) including a noncontact imaging spectrophotometer (MetaVue VS3200; X-Rite), recording data at 2-cm sampling interval. The obtained data is represented in the L*a*b* color coordinate system, where L* is a total reflectance index ranging 0%–100%, a* is green (<0) to red (>0) chromaticity, and b* is blue (<0) to yellow (>0) chromaticity. L*a*b* values were transferred into RGB values using the MATLAB routine lab2rgb. […] |
| Size: |
608 data points |
https://doi.org/10.1594/PANGAEA.975160 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): X-ray diffraction results from IODP Hole 386-M0093A
| Abstract: |
Results of X-ray diffraction (XRD) analyses from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The offshore phase of this expedition took place between 2021-04-13 and 2021-06-01 onboard Japanese R/V Kaimei from and to Yokosuka, Japan, followed by an onshore phase onboard D/V Chikyu between 2022-02-14 – 2022-03-15. During the onshore phase a set of solid-phase samples, with a volume of approx. 10 cubic centimeters each, were taken with the purpose to be later on split into aliquots for the following three analyses: X-ray diffraction, carbon and X-ray fluorescence. The bulk solid-phase samples were taken from the work halves of core sections at about one sample per meter on average. […] |
| Size: |
37 data points |
https://doi.org/10.1594/PANGAEA.978978 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Visual core description of IODP Hole 386-M0090A
| Abstract: |
Collection of visual core description (VCD) sheets (hand drawn originals and digital representations) and lithologic composite plots from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). VCD was performed on unsampled archive halves of split cores, directly after linescan imaging, during the onshore phase of expedition 386, which took place between 2022-02-14 – 2022-03-15 onboard D/V Chikyu. The lithology of each core section is represented on the hand drawn VCDs by graphic patterns next to the X-ray CT image of the archive-half core section. Further, a wide variety of features that characterize the sediment are indicated in additional columns. […] |
| Size: |
12 data points |
https://doi.org/10.1594/PANGAEA.976634 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Total carbon, total organic carbon, total inorganic carbon and total sulfur (solid-phase discrete samples) from IODP Hole 386-M0084C
| Abstract: |
Total carbon (TC), total organic carbon (TOC), total inorganic carbon (TIC) and total sulfur (TS) from solid-phase discrete samples of the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The offshore phase of this expedition took place between 2021-04-13 and 2021-06-01 onboard Japanese R/V Kaimei from and to Yokosuka, Japan, followed by an onshore phase onboard D/V Chikyu between 2022-02-14 – 2022-03-15. During the onshore phase a set of solid-phase samples, with a volume of approx. 10 cubic centimeters each, were taken with the purpose to be later on split into aliquots for the following three analyses: X-ray diffraction, carbon and X-ray fluorescence. The bulk solid-phase samples were taken from the work halves of core sections at about one sample per meter on average. […] |
| Size: |
7 data points |
https://doi.org/10.1594/PANGAEA.975611 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Natural remanent magnetization data from IODP Hole 386-M0091C
| Abstract: |
Natural remanent magnetization (NRM) data from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The offshore phase of this expedition took place between 2021-04-13 and 2021-06-01 onboard Japanese R/V Kaimei from and to Yokosuka, Japan, followed by an onshore phase onboard D/V Chikyu between 2022-02-14 – 2022-03-15. Because the diameter of the split section (12.5 cm) is larger than the magnetometer entrance (8.1 cm), U-channel samples were taken from the center of each working half during the onshore phase. Measurements were conducted likewise during the onshore phase using the long-core superconducting rock magnetometer (2G Enterprises, model 760) installed on D/V Chikyu. Due to time constraints paleomagnetism measurements were limited to NRM with 5 mT demagnetization, with measurements typically made at 2 cm intervals. […] |
| Size: |
120 data points |
https://doi.org/10.1594/PANGAEA.979790 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): Moisture and density (MAD) from IODP Hole 386-M0085D
| Abstract: |
Moisture and density (MAD) data from discrete samples from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). During the onshore phase of expedition 386, which took place between 2022-02-14 – 2022-03-15 onboard D/V Chikyu, discrete samples for MAD measurements (bulk density, dry density, grain density, water content, porosity, and void ratio) were taken from the work halves using 10 cubic centimetre syringes at an approx. down-core resolution of every 2 meters. Sampling depths were adapted and slightly modified for layers of special interest, such as tephras. Samples were processed and measured directly after sampling onboard Chikyu. For the measurements themselves samples were transferred to glass beakers of known weight and volume. […] |
| Size: |
153 data points |
https://doi.org/10.1594/PANGAEA.977448 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): X-Ray fluorescence (XRF) of discrete samples from IODP Hole 386-M0088D
| Abstract: |
Results of X-Ray fluorescence (XRF) on discrete samples from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). The offshore phase of this expedition took place between 2021-04-13 and 2021-06-01 onboard Japanese R/V Kaimei from and to Yokosuka, Japan, followed by an onshore phase onboard D/V Chikyu between 2022-02-14 – 2022-03-15. During the onshore phase a set of solid-phase samples, with a volume of approx. 10 cubic centimeters each, were taken with the purpose to be later on split into aliquots for the following three analyses: X-ray diffraction, carbon and X-ray fluorescence. The bulk solid-phase samples were taken from the work halves of core sections at about one sample per meter on average. […] |
| Size: |
380 data points |
https://doi.org/10.1594/PANGAEA.979592 - Score: 6.184
-
Strasser, M; Ikehara, K; Everest, JD et al. (2025): P-wave velocity of discrete samples (DPW) from IODP Hole 386-M0092B
| Abstract: |
P-wave velocity data from discrete samples from the above given hole of International Ocean Discovery Program (IODP) Expedition 386 (Japan Trench Paleoseismology). During the onshore phase of expedition 386, which took place between 2022-02-14 – 2022-03-15 onboard D/V Chikyu, discrete samples for P-wave velocity measurements were taken from the work halves approx. every 2 meter down core using syringes with an inner diameter of 2 cm. Samples measured 2.5–3 cm long for a sample volume of ~10 cubic centimetres. Samples were then shipped to the European Petrophysics Consortium (EPC) laboratory at the University of Leicester (UK) for processing. Measurements were performed with a Geotek P-wave logger for discrete samples (PWL-D). Measurements were attempted for each sample, however, the unconsolidated lithology of some samples proved unsuitable for the instrument (e.g. too soupy or too friable to be placed between the transducers). […] |
| Size: |
45 data points |
https://doi.org/10.1594/PANGAEA.975314 - Score: 6.184